Condensate pumps - piston & tank pumps
Condensate is formed by the cooling process of air conditioning and refrigeration systems, whereby water is extracted from warm humid air flowing across cold surfaces in the unit cooling coil. In many cases it is not possible to evacuate this collected condensate via a normal gravity feed, this is where our pumps are used to pump the condensate to a convenient drainage point.
EE600 |
EE1000 |
Mini split pump with 2 level float sensor for use with A/C units up to:-
7.5 kW (24 000 BTU)
|
Mini split pump with 3 level float sensor for use with A/C units up to:-
10 kW (34 000 BTU)
|
EE1800 |
PUMPKIN 10 |
Mini split pump with 3 level float sensor for use with A/C units up to:-
20 kW (60 000 BTU)
|
Mini split pump with 2 level float sensor for use with A/C units up to:-
10 kW (34 000 BTU)
|
EE1200Pump kit with trunking and 3 level float sensor for use with A/C units up to:- 10 kW (34 000 BTU)
|
EE1750Split Piston Pump with 3 level float sensor for use with A/C units up to:- 32 kW (100 000 BTU)
|
Silent Centrifugal 120 l/hr 0.2 l capacity tank pump for use with A/C, Fan Coil Units Refrigeration units and furnaces
|
Silent Centrifugal 420 l/hr 1 l capacity tank pump for use with A/C, Fan Coil Units Refrigeration units and furnaces
|
EE400 |
EE1650 |
Super Silent Centrifugal 350 l/hr 0.5 l tank pump for use with A/C, Fan Coil Units, Refrigeration units and furnaces
|
Pump with integrated tank & 3 level float sensor for use with A/C units up to:- 32 kW (100 000 BTU)
|
Product catalogue |
Warranty procedure |
|
|
Fan speed control
ECF2A / ECF4A
EFC 2A (L x W x H): 104 x 68 x 39 mm
EFC 4A (L x W x H): 123 x 79 x 33 mm
Electrical spec.: 230 V, 50 Hz
Electrical load: Fan Motor
max. current 2A/4A (ohmic load)
Regulation:
Phase modulation according sensor temperature and set point 0% or 40% to 100%
at 0%, the fan is off
at 40%, the fan speed is minimum
at 100%, the fan speed is maximum
Sensor: Mounted releasable tie cable length approx. 1 m ends with caps
Application
The EFC Fan Controller is suitable for all air cooled condensing units in air conditioning and refrigeration units with fan motor max. currents up to 2A resp. 4A (ohmic load).
Description
The controller provides not only the correct speed for the outdoor fan, it also decides whether the fan should stop and for how long, to give an optimum control to the system. Furthermore the control avoids an over-condensing even with outdoor temperatures down to -20°C and no iced-up Indoor coils. Due to decreased compressor running time, a higher efficiency will be achieved..
EFC 4A (L x W x H): 123 x 79 x 33 mm
Electrical spec.: 230 V, 50 Hz
Electrical load: Fan Motor
max. current 2A/4A (ohmic load)
Regulation:
Phase modulation according sensor temperature and set point 0% or 40% to 100%
at 0%, the fan is off
at 40%, the fan speed is minimum
at 100%, the fan speed is maximum
Sensor: Mounted releasable tie cable length approx. 1 m ends with caps
Application
The EFC Fan Controller is suitable for all air cooled condensing units in air conditioning and refrigeration units with fan motor max. currents up to 2A resp. 4A (ohmic load).
Description
The controller provides not only the correct speed for the outdoor fan, it also decides whether the fan should stop and for how long, to give an optimum control to the system. Furthermore the control avoids an over-condensing even with outdoor temperatures down to -20°C and no iced-up Indoor coils. Due to decreased compressor running time, a higher efficiency will be achieved..
fancontroller_2a_user_manual.pdf |